  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2014-9201",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2014-9201",
    "idYear": 2014,
    "status": "PUBLISHED",
    "publishedAt": "2015-06-05T10:00:00.000Z",
    "updatedAt": "2024-08-06T13:40:24.594Z",
    "importedAt": "2026-10-24T01:55:44.251Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": null,
      "summary": "Beckwith Electric M-6200 Digital Voltage Regulator Control with firmware before D-0198V04.07.00, M-6200A Digital Voltage Regulator Control with firmware before D-0228V02.01.07, M-2001D Digital Tapchanger Control with firmware before D-0214V01.10.04, M-6283A Three Phase Digital Capacitor Bank Control with firmware before D-0346V03.00.02, M-6280A Digital Capacitor Bank Control with firmware before D-0254V03.05.05, and M-6280 Digital Capacitor Bank Control do not properly generate TCP initial sequence number (ISN) values, which makes it easier for remote attackers to spoof TCP sessions by predicting an ISN value.",
      "affected": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "version": "n/a",
              "status": "affected"
            }
          ]
        }
      ]
    }
  }
}