CVE-2017-20216
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2017
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 Unauthenticated Remote Command Injection
FLIR Thermal Camera PT-Series firmware version 8.0.0.64 contains multiple unauthenticated remote command injection vulnerabilities in the controllerFlirSystem.php script. Attackers can execute arbitrary system commands as root by exploiting unsanitized POST parameters in the execFlirSystem() function through shell_exec() calls. Exploitation evidence was observed by the Shadowserver Foundation on 2026-01-06 (UTC).
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
FLIR Thermal Camera PT-Series
- Vendor
- FLIR Systems, Inc.
- Product
- FLIR Thermal Camera PT-Series
- Platforms
- Unknown
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 8.0.0.64 | affected | Unavailable | Unavailable | Unavailable | None listed |