  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2017-9864",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2017-9864",
    "idYear": 2017,
    "status": "PUBLISHED",
    "publishedAt": "2017-08-05T17:00:00.000Z",
    "updatedAt": "2024-08-05T17:18:02.192Z",
    "importedAt": "2026-10-24T01:55:56.138Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": null,
      "summary": "An issue was discovered in SMA Solar Technology products. An attacker can change the plant time even when not authenticated in any way. This changes the system time, possibly affecting lockout policies and random-number generators based on timestamps, and makes timestamps for data analysis unreliable. NOTE: the vendor reports that this is largely irrelevant because it only affects log-entry timestamps, and because the plant time would later be reset via NTP. (It has never been the case that a lockout policy or random-number generator was affected.) Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected",
      "affected": [
        {
          "vendor": "n/a",
          "product": "n/a",
          "versions": [
            {
              "version": "n/a",
              "status": "affected"
            }
          ]
        }
      ]
    }
  }
}