A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.

Scoped product and version facts

Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.

Exploitation unknown; this catalogue does not assess exploitation.

SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15

Vendor
Siemens AG
Product
SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15
Platforms
Unknown
Default status
Unknown
SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14, SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 : All versionsaffectedUnavailableUnavailableUnavailableNone listed
SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 : All versions < V13 SP2 Update 2affectedUnavailableUnavailableUnavailableNone listed
SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 : All versions < V14 SP1 Update 6affectedUnavailableUnavailableUnavailableNone listed
SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 : All versions < V15 Update 2affectedUnavailableUnavailableUnavailableNone listed