CVE-2019-0064
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2019
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
Junos OS: SRX5000 Series: flowd process crash due to receipt of specific TCP packet
On SRX5000 Series devices, if 'set security zones security-zone <zone> tcp-rst' is configured, the flowd process may crash when a specific TCP packet is received by the device and triggers a new session. The process restarts automatically. However, receipt of a constant stream of these TCP packets may result in an extended Denial of Service (DoS) condition on the device. This issue affects Juniper Networks Junos OS: 18.2R3 on SRX 5000 Series; 18.4R2 on SRX 5000 Series; 19.2R1 on SRX 5000 Series.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
Junos OS
- Vendor
- Juniper Networks
- Product
- Junos OS
- Platforms
- SRX 5000 Series
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 18.2R3 | affected | Unavailable | Unavailable | Unavailable | None listed |
| 18.4R2 | affected | Unavailable | Unavailable | Unavailable | None listed |
| 19.2R1 | affected | Unavailable | Unavailable | Unavailable | None listed |