CVE-2019-10934
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2019
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
A vulnerability has been identified in TIA Portal V14 (All versions), TIA Portal V15 (All versions < V15.1 Update 7), TIA Portal V16 (All versions < V16 Update 6), TIA Portal V17 (All versions < V17 Update 4). Changing the contents of a configuration file could allow an attacker to execute arbitrary code with SYSTEM privileges. The security vulnerability could be exploited by an attacker with a valid account and limited access rights on the system. No user interaction is required. At the time of advisory publication no public exploitation of this security vulnerability was known.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
TIA Portal V14
- Vendor
- Siemens
- Product
- TIA Portal V14
- Platforms
- Unknown
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| All versions | affected | Unavailable | Unavailable | Unavailable | None listed |
TIA Portal V15
- Vendor
- Siemens
- Product
- TIA Portal V15
- Platforms
- Unknown
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| All versions < V15.1 Update 7 | affected | Unavailable | Unavailable | Unavailable | None listed |
TIA Portal V16
- Vendor
- Siemens
- Product
- TIA Portal V16
- Platforms
- Unknown
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| All versions < V16 Update 6 | affected | Unavailable | Unavailable | Unavailable | None listed |
TIA Portal V17
- Vendor
- Siemens
- Product
- TIA Portal V17
- Platforms
- Unknown
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| All versions < V17 Update 4 | affected | Unavailable | Unavailable | Unavailable | None listed |