  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2019-10964",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2019-10964",
    "idYear": 2019,
    "status": "PUBLISHED",
    "publishedAt": "2019-06-28T20:58:07.000Z",
    "updatedAt": "2025-05-22T18:29:15.376Z",
    "importedAt": "2026-10-24T01:56:04.670Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": "Medtronic MiniMed 508 and Paradigm Series Insulin Pumps Improper Access Control",
      "summary": "Medtronic MiniMed Insulin Pumps\n\n are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.",
      "affected": [
        {
          "vendor": "Medtronic",
          "product": "MiniMed 508 pump",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "All versions",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm 511 pump",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "All versions",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm 512/712 pumps",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "All versions",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm 712E pump",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "All versions",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm 515/715 pumps",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "All versions",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm 522/722 pumps",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "All versions",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm 522K/722K pumps",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "All versions",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm 523/723 pumps",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "Software Versions 2.4A"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm 523K/723K pumps",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "Software Versions 2.4A"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm Veo 554/754 pumps",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "Software Versions 2.6A"
            }
          ]
        },
        {
          "vendor": "Medtronic",
          "product": "MiniMed Paradigm Veo 554CM/754CM pumps",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "Software Versions 2.7A"
            }
          ]
        }
      ]
    }
  }
}