RVD#2558: Default credentials on SICK PLC allows disabling safety features

The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

Scoped product and version facts

Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.

Exploitation unknown; this catalogue does not assess exploitation.

MiR100

Vendor
Mobile Industrial Robots A/S
Product
MiR100
Platforms
Unknown
Default status
Unknown
MiR100 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
v2.8.1.1 and beforeaffectedUnavailableUnavailableUnavailableNone listed