  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2020-12526",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2020-12526",
    "idYear": 2020,
    "status": "PUBLISHED",
    "publishedAt": "2021-05-13T13:45:24.098Z",
    "updatedAt": "2024-09-16T18:29:21.532Z",
    "importedAt": "2026-10-24T01:56:12.831Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": "BECKHOFF: DoS-Vulnerability for TwinCAT OPC UA Server and IPC Diagnostics UA Server",
      "summary": "TwinCAT OPC UA Server in versions up to 2.3.0.12 and IPC Diagnostics UA Server in versions up to 3.1.0.1 from Beckhoff Automation GmbH & Co. KG are vulnerable to denial of service attacks. The attacker needs to send several specifically crafted requests to the running OPC UA server. After some of these requests the OPC UA server is no longer responsive to any client. This is without effect to the real-time functionality of IPCs.",
      "affected": [
        {
          "vendor": "Beckhoff",
          "product": "TwinCAT OPC UA Server",
          "versions": [
            {
              "version": "unspecified",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "2.3.0.12"
            }
          ]
        },
        {
          "vendor": "Beckhoff",
          "product": "IPC Diagnostics UA Server",
          "versions": [
            {
              "version": "unspecified",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "3.1.0.1"
            }
          ]
        },
        {
          "vendor": "Beckhoff",
          "product": "TF6100",
          "versions": [
            {
              "version": "unspecified",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "3.3.18"
            }
          ]
        }
      ]
    }
  }
}