CVE-2020-15222
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2020
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
Replay of private_key_jwt possible in ORY Fosite
In ORY Fosite (the security first OAuth2 & OpenID Connect framework for Go) before version 0.31.0, when using "private_key_jwt" authentication the uniqueness of the `jti` value is not checked. When using client authentication method "private_key_jwt", OpenId specification says the following about assertion `jti`: "A unique identifier for the token, which can be used to prevent reuse of the token. These tokens MUST only be used once, unless conditions for reuse were negotiated between the parties". Hydra does not seem to check the uniqueness of this `jti` value. This problem is fixed in version 0.31.0.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
fosite
- Vendor
- ory
- Product
- fosite
- Platforms
- Unknown
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| < 0.31.0 | affected | Unavailable | Unavailable | Unavailable | None listed |