  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2020-15781",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2020-15781",
    "idYear": 2020,
    "status": "PUBLISHED",
    "publishedAt": "2020-08-14T15:24:06.000Z",
    "updatedAt": "2024-08-04T13:22:30.684Z",
    "importedAt": "2026-10-24T01:56:17.081Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": null,
      "summary": "A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application.",
      "affected": [
        {
          "vendor": "Siemens AG",
          "product": "SICAM WEB firmware for SICAM A8000 RTUs",
          "versions": [
            {
              "version": "All versions < V05.30",
              "status": "affected"
            }
          ]
        }
      ]
    }
  }
}