  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2020-16216",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2020-16216",
    "idYear": 2020,
    "status": "PUBLISHED",
    "publishedAt": "2020-09-11T13:06:55.000Z",
    "updatedAt": "2024-08-04T13:37:54.166Z",
    "importedAt": "2026-10-24T01:56:17.081Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": "Philips Patient Monitoring Devices Improper Input Validation",
      "summary": "In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, \nMX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, \nthe product receives input or data but does not validate or incorrectly \nvalidates that the input has the properties required to process the data\n safely and correctly, which can induce a denial-of-service condition \nthrough a system restart.",
      "affected": [
        {
          "vendor": "Philips",
          "product": "IntelliVue patient monitors",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "MX100",
              "status": "affected"
            },
            {
              "version": "MX400-550",
              "status": "affected"
            },
            {
              "version": "MX600",
              "status": "affected"
            },
            {
              "version": "MX700",
              "status": "affected"
            },
            {
              "version": "MX750",
              "status": "affected"
            },
            {
              "version": "MX800",
              "status": "affected"
            },
            {
              "version": "MX850",
              "status": "affected"
            },
            {
              "version": "MP2-MP90",
              "status": "affected"
            }
          ]
        },
        {
          "vendor": "Philips",
          "product": "IntelliVue",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "X2",
              "status": "affected"
            },
            {
              "version": "X3",
              "status": "affected"
            },
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "N"
            }
          ]
        }
      ]
    }
  }
}