A vulnerability has been identified in Mendix Applications using Mendix 7 (All versions < V7.23.31), Mendix Applications using Mendix 8 (All versions < V8.18.18), Mendix Applications using Mendix 9 (All versions < V9.14.0), Mendix Applications using Mendix 9 (V9.12) (All versions < V9.12.2), Mendix Applications using Mendix 9 (V9.6) (All versions < V9.6.12). In case of access to an active user session in an application that is built with an affected version, it’s possible to change that user’s password bypassing password validations within a Mendix application. This could allow to set weak passwords.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
Mendix Applications using Mendix 7
Vendor
Siemens
Product
Mendix Applications using Mendix 7
Platforms
Unknown
Default status
Unknown
Mendix Applications using Mendix 7 · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V7.23.31
affected
Unavailable
Unavailable
Unavailable
None listed
Mendix Applications using Mendix 8
Vendor
Siemens
Product
Mendix Applications using Mendix 8
Platforms
Unknown
Default status
Unknown
Mendix Applications using Mendix 8 · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V8.18.18
affected
Unavailable
Unavailable
Unavailable
None listed
Mendix Applications using Mendix 9
Vendor
Siemens
Product
Mendix Applications using Mendix 9
Platforms
Unknown
Default status
Unknown
Mendix Applications using Mendix 9 · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V9.14.0
affected
Unavailable
Unavailable
Unavailable
None listed
Mendix Applications using Mendix 9 (V9.12)
Vendor
Siemens
Product
Mendix Applications using Mendix 9 (V9.12)
Platforms
Unknown
Default status
Unknown
Mendix Applications using Mendix 9 (V9.12) · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V9.12.2
affected
Unavailable
Unavailable
Unavailable
None listed
Mendix Applications using Mendix 9 (V9.6)
Vendor
Siemens
Product
Mendix Applications using Mendix 9 (V9.6)
Platforms
Unknown
Default status
Unknown
Mendix Applications using Mendix 9 (V9.6) · Scoped product and version facts