A vulnerability has been identified in Parasolid V33.1 (All versions < V33.1.262), Parasolid V34.0 (All versions < V34.0.252), Parasolid V34.1 (All versions < V34.1.242), Parasolid V35.0 (All versions < V35.0.161), Simcenter Femap V2022.1 (All versions < V2022.1.3), Simcenter Femap V2022.2 (All versions < V2022.2.2). The affected application contains an out of bounds write past the end of an allocated buffer while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-17292)
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
Parasolid V33.1
Vendor
Siemens
Product
Parasolid V33.1
Platforms
Unknown
Default status
Unknown
Parasolid V33.1 · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V33.1.262
affected
Unavailable
Unavailable
Unavailable
None listed
Parasolid V34.0
Vendor
Siemens
Product
Parasolid V34.0
Platforms
Unknown
Default status
Unknown
Parasolid V34.0 · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V34.0.252
affected
Unavailable
Unavailable
Unavailable
None listed
Parasolid V34.1
Vendor
Siemens
Product
Parasolid V34.1
Platforms
Unknown
Default status
Unknown
Parasolid V34.1 · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V34.1.242
affected
Unavailable
Unavailable
Unavailable
None listed
Parasolid V35.0
Vendor
Siemens
Product
Parasolid V35.0
Platforms
Unknown
Default status
Unknown
Parasolid V35.0 · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V35.0.161
affected
Unavailable
Unavailable
Unavailable
None listed
Simcenter Femap V2022.1
Vendor
Siemens
Product
Simcenter Femap V2022.1
Platforms
Unknown
Default status
Unknown
Simcenter Femap V2022.1 · Scoped product and version facts
Version (version)
Status (status)
Version scheme (versionType)
Exclusive end (lessThan)
Inclusive end (lessThanOrEqual)
Status changes (at → status)
All versions < V2022.1.3
affected
Unavailable
Unavailable
Unavailable
None listed
Simcenter Femap V2022.2
Vendor
Siemens
Product
Simcenter Femap V2022.2
Platforms
Unknown
Default status
Unknown
Simcenter Femap V2022.2 · Scoped product and version facts