  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2023-23575",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2023-23575",
    "idYear": 2023,
    "status": "PUBLISHED",
    "publishedAt": "2023-04-11T00:00:00.000Z",
    "updatedAt": "2025-02-11T15:46:14.669Z",
    "importedAt": "2026-10-24T01:56:49.724Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": null,
      "summary": "Improper access control vulnerability in CONPROSYS IoT Gateway products allows a remote authenticated attacker to bypass access restriction and access Network Maintenance page, which may result in obtaining the network information of the product. The affected products and versions are as follows: M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131).",
      "affected": [
        {
          "vendor": "Contec CO.,LTD.",
          "product": "CONPROSYS IoT Gateway products",
          "versions": [
            {
              "version": "M2M Gateway with the firmware Ver.3.7.10 and earlier (CPS-MG341-ADSC1-111, CPS-MG341-ADSC1-931, CPS-MG341G-ADSC1-111, CPS-MG341G-ADSC1-930, and CPS-MG341G5-ADSC1-931), M2M Controller Integrated Type with firmware Ver.3.7.6 and earlier versions (CPS-MC341-ADSC1-111, CPS-MC341-ADSC1-931, CPS-MC341-ADSC2-111, CPS-MC341G-ADSC1-110, CPS-MC341Q-ADSC1-111, CPS-MC341-DS1-111, CPS-MC341-DS11-111, CPS-MC341-DS2-911, and CPS-MC341-A1-111), and M2M Controller Configurable Type with firmware Ver.3.8.8 and earlier versions (CPS-MCS341-DS1-111, CPS-MCS341-DS1-131, CPS-MCS341G-DS1-130, CPS-MCS341G5-DS1-130, and CPS-MCS341Q-DS1-131)",
              "status": "affected"
            }
          ]
        }
      ]
    }
  }
}