- Record status
- Published
- Identifier year (not publication year)
- 2023
- Source publication
- Source updated
- Imported by cveboard
CNA source text (English)
A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
SIMATIC STEP 7 Safety V16
- Vendor
- Siemens
- Product
- SIMATIC STEP 7 Safety V16
- Platforms
- Unknown
- Default status
unknown
SIMATIC STEP 7 Safety V16 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V16 Update 7 | Unavailable | None listed |
|---|
SIMATIC STEP 7 Safety V17
- Vendor
- Siemens
- Product
- SIMATIC STEP 7 Safety V17
- Platforms
- Unknown
- Default status
unknown
SIMATIC STEP 7 Safety V17 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V17 Update 7 | Unavailable | None listed |
|---|
SIMATIC STEP 7 Safety V18
- Vendor
- Siemens
- Product
- SIMATIC STEP 7 Safety V18
- Platforms
- Unknown
- Default status
unknown
SIMATIC STEP 7 Safety V18 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V18 Update 2 | Unavailable | None listed |
|---|
SIMATIC STEP 7 V16
- Vendor
- Siemens
- Product
- SIMATIC STEP 7 V16
- Platforms
- Unknown
- Default status
unknown
SIMATIC STEP 7 V16 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V16 Update 7 | Unavailable | None listed |
|---|
SIMATIC STEP 7 V17
- Vendor
- Siemens
- Product
- SIMATIC STEP 7 V17
- Platforms
- Unknown
- Default status
unknown
SIMATIC STEP 7 V17 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V17 Update 7 | Unavailable | None listed |
|---|
SIMATIC STEP 7 V18
- Vendor
- Siemens
- Product
- SIMATIC STEP 7 V18
- Platforms
- Unknown
- Default status
unknown
SIMATIC STEP 7 V18 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V18 Update 2 | Unavailable | None listed |
|---|
SIMATIC WinCC Unified V16
- Vendor
- Siemens
- Product
- SIMATIC WinCC Unified V16
- Platforms
- Unknown
- Default status
unknown
SIMATIC WinCC Unified V16 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V16 Update 7 | Unavailable | None listed |
|---|
SIMATIC WinCC Unified V17
- Vendor
- Siemens
- Product
- SIMATIC WinCC Unified V17
- Platforms
- Unknown
- Default status
unknown
SIMATIC WinCC Unified V17 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V17 Update 7 | Unavailable | None listed |
|---|
SIMATIC WinCC Unified V18
- Vendor
- Siemens
- Product
- SIMATIC WinCC Unified V18
- Platforms
- Unknown
- Default status
unknown
SIMATIC WinCC Unified V18 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V18 Update 2 | Unavailable | None listed |
|---|
SIMATIC WinCC V16
- Vendor
- Siemens
- Product
- SIMATIC WinCC V16
- Platforms
- Unknown
- Default status
unknown
SIMATIC WinCC V16 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V16.7 | Unavailable | None listed |
|---|
SIMATIC WinCC V17
- Vendor
- Siemens
- Product
- SIMATIC WinCC V17
- Platforms
- Unknown
- Default status
unknown
SIMATIC WinCC V17 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V17.7 | Unavailable | None listed |
|---|
SIMATIC WinCC V18
- Vendor
- Siemens
- Product
- SIMATIC WinCC V18
- Platforms
- Unknown
- Default status
unknown
SIMATIC WinCC V18 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V18 Update 2 | Unavailable | None listed |
|---|
SIMOCODE ES V16
- Vendor
- Siemens
- Product
- SIMOCODE ES V16
- Platforms
- Unknown
- Default status
unknown
SIMOCODE ES V16 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V16 Update 7 | Unavailable | None listed |
|---|
SIMOCODE ES V17
- Vendor
- Siemens
- Product
- SIMOCODE ES V17
- Platforms
- Unknown
- Default status
unknown
SIMOCODE ES V17 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V17 Update 7 | Unavailable | None listed |
|---|
SIMOCODE ES V18
- Vendor
- Siemens
- Product
- SIMOCODE ES V18
- Platforms
- Unknown
- Default status
unknown
SIMOCODE ES V18 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V18 Update 2 | Unavailable | None listed |
|---|
SIMOTION SCOUT TIA V5.4 SP1
- Vendor
- Siemens
- Product
- SIMOTION SCOUT TIA V5.4 SP1
- Platforms
- Unknown
- Default status
unknown
SIMOTION SCOUT TIA V5.4 SP1 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | * | Unavailable | None listed |
|---|
SIMOTION SCOUT TIA V5.4 SP3
- Vendor
- Siemens
- Product
- SIMOTION SCOUT TIA V5.4 SP3
- Platforms
- Unknown
- Default status
unknown
SIMOTION SCOUT TIA V5.4 SP3 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | * | Unavailable | None listed |
|---|
SIMOTION SCOUT TIA V5.5 SP1
- Vendor
- Siemens
- Product
- SIMOTION SCOUT TIA V5.5 SP1
- Platforms
- Unknown
- Default status
unknown
SIMOTION SCOUT TIA V5.5 SP1 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | * | Unavailable | None listed |
|---|
SINAMICS Startdrive V16
- Vendor
- Siemens
- Product
- SINAMICS Startdrive V16
- Platforms
- Unknown
- Default status
unknown
SINAMICS Startdrive V16 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | * | Unavailable | None listed |
|---|
SINAMICS Startdrive V17
- Vendor
- Siemens
- Product
- SINAMICS Startdrive V17
- Platforms
- Unknown
- Default status
unknown
SINAMICS Startdrive V17 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | * | Unavailable | None listed |
|---|
SINAMICS Startdrive V18
- Vendor
- Siemens
- Product
- SINAMICS Startdrive V18
- Platforms
- Unknown
- Default status
unknown
SINAMICS Startdrive V18 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | * | Unavailable | None listed |
|---|
SIRIUS Safety ES V17
- Vendor
- Siemens
- Product
- SIRIUS Safety ES V17
- Platforms
- Unknown
- Default status
unknown
SIRIUS Safety ES V17 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V17 Update 7 | Unavailable | None listed |
|---|
SIRIUS Safety ES V18
- Vendor
- Siemens
- Product
- SIRIUS Safety ES V18
- Platforms
- Unknown
- Default status
unknown
SIRIUS Safety ES V18 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V18 Update 2 | Unavailable | None listed |
|---|
SIRIUS Soft Starter ES V17
- Vendor
- Siemens
- Product
- SIRIUS Soft Starter ES V17
- Platforms
- Unknown
- Default status
unknown
SIRIUS Soft Starter ES V17 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V17 Update 7 | Unavailable | None listed |
|---|
SIRIUS Soft Starter ES V18
- Vendor
- Siemens
- Product
- SIRIUS Soft Starter ES V18
- Platforms
- Unknown
- Default status
unknown
SIRIUS Soft Starter ES V18 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V18 Update 2 | Unavailable | None listed |
|---|
Soft Starter ES V16
- Vendor
- Siemens
- Product
- Soft Starter ES V16
- Platforms
- Unknown
- Default status
unknown
Soft Starter ES V16 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V16 Update 7 | Unavailable | None listed |
|---|
TIA Portal Cloud V3.0
- Vendor
- Siemens
- Product
- TIA Portal Cloud V3.0
- Platforms
- Unknown
- Default status
unknown
TIA Portal Cloud V3.0 · Scoped product and version facts| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
| 0 | affected | custom | V18 Update 2 | Unavailable | None listed |
|---|