cveboard RSS feed

CVE-2023-50916

CVE.org · Published

Historical CVEsJSONAI instructions

Record status
Published
Identifier year (not publication year)
2023
Source publication
Source updated
Imported by cveboard
Source snapshot
cve_2026-10-24_midnight_baseline ·

Plain text

CNA source text (English)

Kyocera Device Manager before 3.1.1213.0 allows NTLM credential exposure during UNC path authentication via a crafted change from a local path to a UNC path. It allows administrators to configure the backup location of the database used by the application. Attempting to change this location to a UNC path via the GUI is rejected due to the use of a \ (backslash) character, which is supposed to be disallowed in a pathname. Intercepting and modifying this request via a proxy, or sending the request directly to the application endpoint, allows UNC paths to be set for the backup location. Once such a location is set, Kyocera Device Manager attempts to confirm access and will try to authenticate to the UNC path; depending on the configuration of the environment, this may authenticate to the UNC with Windows NTLM hashes. This could allow NTLM credential relaying or cracking attacks.

Scoped product and version facts

Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.

Exploitation unknown; this catalogue does not assess exploitation.

n/a

Vendor
n/a
Product
n/a
Platforms
Unknown
Default status
Unknown
n/a · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
n/aaffectedUnavailableUnavailableUnavailableNone listed