Kyocera Device Manager before 3.1.1213.0 allows NTLM credential exposure during UNC path authentication via a crafted change from a local path to a UNC path. It allows administrators to configure the backup location of the database used by the application. Attempting to change this location to a UNC path via the GUI is rejected due to the use of a \ (backslash) character, which is supposed to be disallowed in a pathname. Intercepting and modifying this request via a proxy, or sending the request directly to the application endpoint, allows UNC paths to be set for the backup location. Once such a location is set, Kyocera Device Manager attempts to confirm access and will try to authenticate to the UNC path; depending on the configuration of the environment, this may authenticate to the UNC with Windows NTLM hashes. This could allow NTLM credential relaying or cracking attacks.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
n/a