  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2024-10771",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2024-10771",
    "idYear": 2024,
    "status": "PUBLISHED",
    "publishedAt": "2024-12-06T12:24:40.610Z",
    "updatedAt": "2026-05-13T12:04:13.962Z",
    "importedAt": "2026-10-24T01:57:03.413Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": "SICK InspectorP61x, SICK InspectorP62x and SICK TiM3xx are vulnerable for remote code execution",
      "summary": "Due to missing input validation during one step of the firmware update process, the product\nis vulnerable to remote code execution. With network access and the user level ”Service”, an attacker\ncan execute arbitrary system commands in the root user’s contexts.",
      "affected": [
        {
          "vendor": "SICK AG",
          "product": "SICK InspectorP61x",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "<5.0.0"
            }
          ]
        },
        {
          "vendor": "SICK AG",
          "product": "SICK InspectorP62x",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "<5.0.0"
            }
          ]
        },
        {
          "vendor": "SICK AG",
          "product": "TiM3xx",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "<5.10.0"
            }
          ]
        },
        {
          "vendor": "SICK AG",
          "product": "TDC-X401GL",
          "defaultStatus": "affected",
          "versions": [
            {
              "version": "all versions",
              "status": "affected"
            }
          ]
        }
      ]
    }
  }
}