CVE-2024-23485
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2024
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
Improperly Preserved Integrity of Hardware Configuration State During a Power Save/Restore Operation (CWE-1304) in the Controller 6000 and 7000 can lead to secured door locks connected via Aperio Communication Hubs to momentarily allow free access. This issue affects: Gallagher Controller 6000 and 7000 9.10 prior to vCR9.10.240520a (distributed in 9.10.1268(MR1)), 9.00 prior to vCR9.00.240521a (distributed in 9.00.1990(MR3)), 8.90 prior to vCR8.90.240520a (distributed in 8.90.1947 (MR4)), 8.80 prior to vCR8.80.240520a (distributed in 8.80.1726 (MR5)), 8.70 prior to vCR8.70.240520a (distributed in 8.70.2824 (MR7)), all versions of 8.60 and prior.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
Controller 6000 and Controller 7000
- Vendor
- Gallagher
- Product
- Controller 6000 and Controller 7000
- Platforms
- Unknown
- Default status
affected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 9.10 | affected | custom | vCR9.10.240520a | Unavailable | None listed |
| 9.00 | affected | custom | vCR9.00.240521a | Unavailable | None listed |
| 8.90 | affected | custom | vCR8.90.240520a | Unavailable | None listed |
| 8.80 | affected | custom | vCR8.80.240520a | Unavailable | None listed |
| 8.70 | affected | custom | vCR8.70.240520a | Unavailable | None listed |
| 0 | affected | custom | Unavailable | 8.60 | None listed |