  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2024-24972",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2024-24972",
    "idYear": 2024,
    "status": "PUBLISHED",
    "publishedAt": "2024-09-11T04:03:18.609Z",
    "updatedAt": "2024-09-11T13:37:28.096Z",
    "importedAt": "2026-10-24T01:57:07.518Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": null,
      "summary": "Buffer Copy without Checking Size of Input (CWE-120) in the Controller 6000 and Controller 7000 diagnostic web interface allows an authorised and authenticated operator to reboot the Controller, causing a Denial of Service. Gallagher recommend the diagnostic web page is not enabled (default is off) unless advised by Gallagher Technical support. This interface is intended only for diagnostic purposes.\n\nThis issue affects: Controller 6000 and Controller 7000 9.10 prior to vCR9.10.240816a (distributed in 9.10.1530 (MR2)), 9.00 prior to vCR9.00.240816a (distributed in 9.00.2168 (MR4)), 8.90 prior to vCR8.90.240816a (distributed in 8.90.2155 (MR5)), 8.80 prior to vCR8.80.240816b (distributed in 8.80.1938 (MR6)), all versions of 8.70 and prior.",
      "affected": [
        {
          "vendor": "Gallagher",
          "product": "Controller 6000 and Controller 7000",
          "defaultStatus": "affected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "8.70"
            },
            {
              "version": "9.10",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "vCR9.10.240816a"
            },
            {
              "version": "9.00",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "vCR9.00.240816a"
            },
            {
              "version": "8.90",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "vCR8.90.240816a"
            },
            {
              "version": "8.80",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "vCR8.80.240816b"
            }
          ]
        }
      ]
    }
  }
}