CVE-2024-26293
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2024
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
Unauthenticated Path Traversal affecting Avid NEXIS
The Avid Nexis Agent uses a vulnerable gSOAP version. An undocumented vulnerability impacting gSOAP v2.8 makes the application vulnerable to an Unauthenticated Path Traversal vulnerability. This issue affects Avid NEXIS E-series: before 2025.5.1; Avid NEXIS F-series: before 2025.5.1; Avid NEXIS PRO+: before 2025.5.1; System Director Appliance (SDA+): before 2025.5.1.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
Avid NEXIS E-series
- Vendor
- Avid
- Product
- Avid NEXIS E-series
- Platforms
- Linux
- Windows
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 0 | affected | custom | 2025.5.1 | Unavailable | None listed |
Avid NEXIS F-series
- Vendor
- Avid
- Product
- Avid NEXIS F-series
- Platforms
- Linux
- Windows
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 0 | affected | custom | 2025.5.1 | Unavailable | None listed |
Avid NEXIS PRO+
- Vendor
- Avid
- Product
- Avid NEXIS PRO+
- Platforms
- Linux
- windows
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 0 | affected | custom | 2025.5.1 | Unavailable | None listed |
System Director Appliance (SDA+)
- Vendor
- Avid
- Product
- System Director Appliance (SDA+)
- Platforms
- Linux
- Windows
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|