  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2024-2637",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2024-2637",
    "idYear": 2024,
    "status": "PUBLISHED",
    "publishedAt": "2024-05-14T18:49:28.624Z",
    "updatedAt": "2025-04-24T06:52:46.092Z",
    "importedAt": "2026-10-24T01:57:11.582Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": "Insecure Loading of Code in B&R Products",
      "summary": "An Uncontrolled Search Path Element vulnerability in B&R Industrial Automation Scene Viewer, B&R Industrial Automation Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4, B&R Industrial Automation APROL, B&R Industrial Automation CAN Driver, B&R Industrial Automation CAN Driver CC770, B&R Industrial Automation CAN Driver SJA1000, B&R Industrial Automation Tou0ch Lock, B&R Industrial Automation B&R Single-Touch Driver, B&R Industrial Automation Serial User Mode Touch Driver, B&R Industrial Automation Windows Settings Changer (LTSC), B&R Industrial Automation Windows Settings Changer (2019 LTSC), B&R Industrial Automation Windows 10 Recovery Solution, B&R Industrial Automation ADI driver universal, B&R Industrial Automation ADI Development Kit, B&R Industrial Automation ADI .NET SDK, B&R Industrial Automation SRAM driver, B&R Industrial Automation HMI Service Center, B&R Industrial Automation HMI Service Center Maintenance, B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0.",
      "affected": [
        {
          "vendor": "B&R Industrial Automation",
          "product": "Scene Viewer",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "4.4.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "Automation Runtime",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "J4.93"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "mapp Vision",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "5.26.1"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "mapp View",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "5.24.2"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "mapp Cockpit",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "5.24.2"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "mapp Safety",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "5.24.2"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "VC4",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "4.73.2"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "APROL",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "4.4-01"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "CAN Driver",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "1.1.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "CAN Driver CC770",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "3.3.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "CAN Driver SJA1000",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "1.3.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "Tou0ch Lock",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "2.1.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "B&R Single-Touch Driver",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "2.0.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "Serial User Mode Touch Driver",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "1.7.1"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "Windows Settings Changer (LTSC)",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "3.2.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "Windows Settings Changer (2019 LTSC)",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "2.2.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "Windows 10 Recovery Solution",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "3.2.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "ADI driver universal",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "3.2.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "ADI Development Kit",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "5.5.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "ADI .NET SDK",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "4.1.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "SRAM driver",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "1.2.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "HMI Service Center",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "3.1.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "HMI Service Center Maintenance",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "2.1.0"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "Windows 10 IoT Enterprise 2019 LTSC",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "1.1"
            }
          ]
        },
        {
          "vendor": "B&R Industrial Automation",
          "product": "KCF Editor",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "1.1.0"
            }
          ]
        }
      ]
    }
  }
}