A vulnerability has been identified in COMOS V10.3 (All versions < V10.3.3.5.8), COMOS V10.4.0 (All versions), COMOS V10.4.1 (All versions), COMOS V10.4.2 (All versions), COMOS V10.4.3 (All versions < V10.4.3.0.47), COMOS V10.4.4 (All versions < V10.4.4.2), COMOS V10.4.4.1 (All versions < V10.4.4.1.21). The PDMS/E3D Engineering Interface improperly handles XML External Entity (XXE) entries when communicating with an external application. This could allow an attacker to extract any file with a known location on the user's system or accessible network folders by injecting malicious data into the communication channel between the two systems.

Scoped product and version facts

Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.

Exploitation unknown; this catalogue does not assess exploitation.

COMOS V10.3

Vendor
Siemens
Product
COMOS V10.3
Platforms
Unknown
Default status
unknown
COMOS V10.3 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
0affectedcustomV10.3.3.5.8UnavailableNone listed

COMOS V10.4.0

Vendor
Siemens
Product
COMOS V10.4.0
Platforms
Unknown
Default status
unknown
COMOS V10.4.0 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
0affectedcustom*UnavailableNone listed

COMOS V10.4.1

Vendor
Siemens
Product
COMOS V10.4.1
Platforms
Unknown
Default status
unknown
COMOS V10.4.1 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
0affectedcustom*UnavailableNone listed

COMOS V10.4.2

Vendor
Siemens
Product
COMOS V10.4.2
Platforms
Unknown
Default status
unknown
COMOS V10.4.2 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
0affectedcustom*UnavailableNone listed

COMOS V10.4.3

Vendor
Siemens
Product
COMOS V10.4.3
Platforms
Unknown
Default status
unknown
COMOS V10.4.3 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
0affectedcustomV10.4.3.0.47UnavailableNone listed

COMOS V10.4.4

Vendor
Siemens
Product
COMOS V10.4.4
Platforms
Unknown
Default status
unknown
COMOS V10.4.4 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
0affectedcustomV10.4.4.2UnavailableNone listed

COMOS V10.4.4.1

Vendor
Siemens
Product
COMOS V10.4.4.1
Platforms
Unknown
Default status
unknown
COMOS V10.4.4.1 · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
0affectedcustomV10.4.4.1.21UnavailableNone listed