  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2024-54092",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2024-54092",
    "idYear": 2024,
    "status": "PUBLISHED",
    "publishedAt": "2025-04-08T08:22:24.861Z",
    "updatedAt": "2025-07-08T10:34:27.627Z",
    "importedAt": "2026-10-24T01:57:20.494Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": null,
      "summary": "A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.",
      "affected": [
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - arm64 V1.17",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "*"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - arm64 V1.18",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "*"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - arm64 V1.19",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "*"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - arm64 V1.20",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V1.20.2-1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - arm64 V1.21",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V1.21.1-1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - x86-64 V1.17",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "*"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - x86-64 V1.18",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "*"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - x86-64 V1.19",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "*"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - x86-64 V1.20",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V1.20.2-1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Device Kit - x86-64 V1.21",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V1.21.1-1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Own Device (IEOD)",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V1.21.1-1-a"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Industrial Edge Virtual Device",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V1.21.1-1-a"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SCALANCE LPE9413",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC BX-39A Industrial Edge Device",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V3.0"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC BX-59A Industrial Edge Device",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V3.0"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC127E Industrial Edge Device",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V3.0"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC227E Industrial Edge Device",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V3.0"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC427E Industrial Edge Device",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V3.0"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "SIMATIC IPC847E Industrial Edge Device",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V3.0"
            }
          ]
        }
      ]
    }
  }
}