Unauthenticated modification of Radiflow iSAP Smart Collector configuration

An unauthenticated user with management network access can get and modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration and execute some commands (e.g., system reboot).

Scoped product and version facts

Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.

Exploitation unknown; this catalogue does not assess exploitation.

iSAP Smart Collector

Vendor
Radiflow
Product
iSAP Smart Collector
Platforms
  • Linux
Default status
unaffected
iSAP Smart Collector · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
1.20affectedsemver3.02-1UnavailableNone listed