  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2025-40945",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2025-40945",
    "idYear": 2025,
    "status": "PUBLISHED",
    "publishedAt": "2026-07-14T09:19:08.857Z",
    "updatedAt": "2026-07-14T12:16:59.871Z",
    "importedAt": "2026-10-24T01:57:34.152Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": null,
      "summary": "A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access.",
      "affected": [
        {
          "vendor": "Siemens",
          "product": "COMOS V10.4.5",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V10.4.5.0.2"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "COMOS V10.6",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V10.6.1"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Designcenter NX",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2512.7000"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter 3D",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2512.7000"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter Femap V2506",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2506.0003"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter Femap V2512",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2512.0002"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter Nastran",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2606"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Simcenter STAR-CCM+",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2606"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Solid Edge SE2025",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V225.0 Update 13"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Solid Edge SE2026",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V226.0 Update 04"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V2412",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2412.0012"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V2506",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2506.0009"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Teamcenter Visualization V2512",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2512.2605"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Tecnomatix Plant Simulation V2404",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2404.0022"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Tecnomatix Plant Simulation V2504",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2504.0010"
            }
          ]
        },
        {
          "vendor": "Siemens",
          "product": "Tecnomatix Process Simulate",
          "defaultStatus": "unknown",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThan": "V2606"
            }
          ]
        }
      ]
    }
  }
}