CVE-2025-5191
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2025
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
Unquoted Search Path Vulnerability in the Utility for Industrial Computers (Windows)
An Unquoted Search Path vulnerability has been identified in the utility for Moxa’s industrial computers (Windows). Due to the unquoted path configuration in the SerialInterfaceService.exe utility, a local attacker with limited privileges could place a malicious executable in a higher-priority directory within the search path. When the Serial Interface service starts, the malicious executable could be run with SYSTEM privileges. Successful exploitation could allow privilege escalation or enable an attacker to maintain persistence on the affected system. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality, integrity, or availability within any subsequent systems.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
Utility for DRP-A100 Series
- Vendor
- Moxa
- Product
- Utility for DRP-A100 Series
- Platforms
- Windows 10 IoT Enterprise LTSC 2021
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 1.0 | affected | custom | Unavailable | 1.1 | None listed |
| 1.2 | unaffected | custom | Unavailable | Unavailable | None listed |
Utility for DRP-A100 Series
- Vendor
- Moxa
- Product
- Utility for DRP-A100 Series
- Platforms
- Windows 11 IoT Enterprise LTSC 2024
- Windows 11 Professional 2022
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 1.0 | affected | custom | Unavailable | Unavailable | None listed |
| 1.1 | unaffected | custom | Unavailable | Unavailable | None listed |
Utility for DRP-C100 Series
- Vendor
- Moxa
- Product
- Utility for DRP-C100 Series
- Platforms
- Windows 10 IoT Enterprise LTSC 2021
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 1.0 | affected | custom | Unavailable | 1.1 | None listed |
| 1.2 | unaffected | custom | Unavailable | Unavailable | None listed |
Utility for DRP-C100 Series
- Vendor
- Moxa
- Product
- Utility for DRP-C100 Series
- Platforms
- Windows 11 IoT Enterprise LTSC 2024
- Windows 11 Professional 2022
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 1.0 | affected | custom | Unavailable | Unavailable | None listed |
| 1.1 | unaffected | custom | Unavailable | Unavailable | None listed |