RCE via the poller reload feature available only to user with high privilege
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Centreon Infra Monitoring (Poller reload setup in the configuration modules) allows OS Command Injection. On the poller parameters page, a user with high privilege is able to concatenate custom instructions into the poller reload command. This issue affects Infra Monitoring: from 24.10.0 before 24.10.13, from 24.04.0 before 24.04.18, from 23.10.0 before 23.10.28.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
Infra Monitoring
- Vendor
- Centreon
- Product
- Infra Monitoring
- Platforms
- Unknown
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 24.10.0 | affected | custom | 24.10.13 | Unavailable | None listed |
| 24.04.0 | affected | custom | 24.04.18 | Unavailable | None listed |
| 23.10.0 | affected | custom | 23.10.28 | Unavailable | None listed |