CVE-2025-69426
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2025
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded SSH Credentials RCE
The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) contain hardcoded credentials for an operating system user account within an initialization script. The SSH service is network-accessible without IP-based restrictions. Although the configuration disables SCP and pseudo-TTY allocation, an attacker can authenticate using the hardcoded credentials and establish SSH local port forwarding to access the Docker socket. By mounting the host filesystem via Docker, an attacker can escape the container and execute arbitrary OS commands as root on the underlying vRIoT controller, resulting in complete system compromise.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
vRIoT IOT Controller
- Vendor
- RUCKUS Networks
- Product
- vRIoT IOT Controller
- Platforms
- Unknown
- Default status
unaffected
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 2.3.0.0 (GA) | affected | custom | 3.0.0.0 (GA) | Unavailable | None listed |
| 2.3.1.0 (MR) | affected | custom | 3.0.0.0 (GA) | Unavailable | None listed |
| 2.4.0.0 (GA) | affected | custom | 3.0.0.0 (GA) | Unavailable | None listed |