cveboard RSS feed

CVE-2025-71284

CVE.org · Published

Historical CVEsJSONAI instructions

Record status
Published
Identifier year (not publication year)
2025
Source publication
Source updated
Imported by cveboard
Source snapshot
cve_2026-10-24_midnight_baseline ·

Plain text

CNA source text (English)

Synway SMG Gateway Management Software OS Command Injection via radius_address

Synway SMG Gateway Management Software contains an OS command injection vulnerability in the RADIUS configuration endpoint at /en/9-2radius.php where the radius_address POST parameter is split and interpolated directly into a sed command without sanitization. An unauthenticated remote attacker can inject arbitrary shell commands by submitting a POST request with crafted radius_address, radius_address2, shared_secret2, source_ip, timeout, or retry parameters along with save=1 and enable_radius=1 to achieve remote code execution. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-07-11 (UTC).

Scoped product and version facts

Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.

Exploitation unknown; this catalogue does not assess exploitation.

Synway SMG Gateway Management Software

Vendor
Synway Information Engineering Co., Ltd.
Product
Synway SMG Gateway Management Software
Platforms
Unknown
Default status
affected
Synway SMG Gateway Management Software · Scoped product and version facts
Version (version)Status (status)Version scheme (versionType)Exclusive end (lessThan)Inclusive end (lessThanOrEqual)Status changes (at → status)
0affectedsemverUnavailableUnavailableNone listed