  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2026-16675",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2026-16675",
    "idYear": 2026,
    "status": "PUBLISHED",
    "publishedAt": "2026-09-01T13:18:58.120Z",
    "updatedAt": "2026-09-01T15:42:20.636Z",
    "importedAt": "2026-10-24T01:57:55.771Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": "Rockwell Automation FactoryTalk® Activation Manager - Privilege Escalation",
      "summary": "A privilege escalation security issue exists within FactoryTalk® Activation Manager. The security issue stems from custom actions in the installer that spawn visible console windows running with SYSTEM privileges during installation or repair operations. An authenticated attacker with Windows credentials could hijack these console windows to obtain a SYSTEM-level command prompt, allowing full access to all files, processes, and system resources.",
      "affected": [
        {
          "vendor": "Rockwell Automation",
          "product": "FactoryTalk® Activation Manager",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "Version 5.02 and below",
              "status": "affected"
            }
          ]
        }
      ]
    }
  }
}