HTSlib CRAM reader has out-of-bounds reads due to improper validation of input
HTSlib is a library for reading and writing bioinformatics file formats. CRAM is a compressed format which stores DNA sequence alignment data. In the `cram_decode_slice()` function called while reading CRAM records, validation of the reference id field occurred too late, allowing two out of bounds reads to occur before the invalid data was detected. The bug does allow two values to be leaked to the caller, however as the function reports an error it may be difficult to exploit them. It is also possible that the program will crash due to trying to access invalid memory. Versions 1.23.1, 1.22.2 and 1.21.1 include fixes for this issue. There is no workaround for this issue.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
htslib
- Vendor
- samtools
- Product
- htslib
- Platforms
- Unknown
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| < 1.21.1 | affected | Unavailable | Unavailable | Unavailable | None listed |
| >= 1.22, < 1.22.2 | affected | Unavailable | Unavailable | Unavailable | None listed |