  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2026-34775",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2026-34775",
    "idYear": 2026,
    "status": "PUBLISHED",
    "publishedAt": "2026-04-03T23:55:20.950Z",
    "updatedAt": "2026-04-08T03:55:39.764Z",
    "importedAt": "2026-10-24T01:58:08.712Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": "Electron: nodeIntegrationInWorker not correctly scoped in shared renderer processes",
      "summary": "Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 38.8.6, 39.8.4, 40.8.4, and 41.0.0, the nodeIntegrationInWorker webPreference was not correctly scoped in all configurations. In certain process-sharing scenarios, workers spawned in frames configured with nodeIntegrationInWorker: false could still receive Node.js integration. Apps are only affected if they enable nodeIntegrationInWorker. Apps that do not use nodeIntegrationInWorker are not affected. This issue has been patched in versions 38.8.6, 39.8.4, 40.8.4, and 41.0.0.",
      "affected": [
        {
          "vendor": "electron",
          "product": "electron",
          "versions": [
            {
              "version": "< 38.8.6",
              "status": "affected"
            },
            {
              "version": ">= 39.0.0-alpha.1, < 39.8.4",
              "status": "affected"
            },
            {
              "version": ">= 40.0.0-alpha.1, < 40.8.4",
              "status": "affected"
            },
            {
              "version": ">= 41.0.0-alpha.1, < 41.0.0",
              "status": "affected"
            }
          ]
        }
      ]
    }
  }
}