PicoTronica e-Clinic Healthcare System ECHS API Endpoint patient-records missing authentication
A vulnerability was detected in PicoTronica e-Clinic Healthcare System ECHS 5.7. The affected element is an unknown function of the file /cdemos/echs/api/v2/patient-records of the component API Endpoint. The manipulation results in missing authentication. The attack can be executed remotely. The exploit is now public and may be used. Upgrading to version 5.7.1 is sufficient to fix this issue. You should upgrade the affected component. The vendor was contacted early, responded in a very professional manner and quickly released a fixed version of the affected product.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
e-Clinic Healthcare System ECHS
- Vendor
- PicoTronica
- Product
- e-Clinic Healthcare System ECHS
- Platforms
- Unknown
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| 5.7 | affected | Unavailable | Unavailable | Unavailable | None listed |
| 5.7.1 | unaffected | Unavailable | Unavailable | Unavailable | None listed |