  "schemaVersion": 1,
  "attribution": [
    {
      "source": "CISA Known Exploited Vulnerabilities",
      "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog",
      "licence": "US government work"
    },
    {
      "source": "GitHub Advisory Database",
      "url": "https://github.com/advisories",
      "licence": "CC BY 4.0"
    },
    {
      "source": "Have I Been Pwned",
      "url": "https://haveibeenpwned.com/",
      "licence": "CC BY 4.0"
    },
    {
      "source": "CVE Program (CVE records)",
      "url": "https://www.cve.org/Legal/TermsOfUse",
      "licence": "CVE Terms of Use",
      "notice": "Copyright © 1999-2026, The MITRE Corporation. CVE is a trademark and the CVE logo is a registered trademark of The MITRE Corporation.",
      "terms": "CVE Usage: MITRE hereby grants you a perpetual, worldwide, non-exclusive, no-charge, royalty-free, irrevocable copyright license to reproduce, prepare derivative works of, publicly display, publicly perform, sublicense, and distribute Common Vulnerabilities and Exposures (CVE™). Any copy you make for such purposes is authorized provided that you reproduce MITRE's copyright designation and this license in any such copy."
    },
    {
      "source": "FIRST EPSS",
      "url": "https://www.first.org/epss/",
      "licence": "free to use; FIRST requests attribution"
    }
  ],
  "record": {
    "id": "CVE-2026-82567",
    "sourceURL": "https://www.cve.org/CVERecord?id=CVE-2026-82567",
    "idYear": 2026,
    "status": "PUBLISHED",
    "publishedAt": "2026-09-15T21:45:45.922Z",
    "updatedAt": "2026-09-16T18:11:13.093Z",
    "importedAt": "2026-10-24T01:58:30.346Z",
    "snapshot": {
      "id": "cve_2026-10-24_midnight_baseline",
      "at": "2026-10-24T00:00:00.000Z",
      "source": "https://github.com/CVEProject/cvelistV5/releases/tag/cve_2026-10-24_0100Z"
    },
    "facts": {
      "title": "mySCADA myPRO Manager Missing Authorization",
      "summary": "The myPRO Manager notification gateway exposes an unauthenticated HTTP endpoint used to send SMS messages through a connected GSM modem. The endpoint is accessible over the network and does not require authentication before accepting a phone number and message from a request and sending the specified SMS message. An unauthenticated attacker with network access to the notification gateway could exploit this vulnerability to send arbitrary SMS messages through the connected modem.",
      "affected": [
        {
          "vendor": "mySCADA Technologies",
          "product": "mySCADA myPRO",
          "defaultStatus": "unaffected",
          "versions": [
            {
              "version": "0",
              "status": "affected",
              "versionType": "custom",
              "lessThanOrEqual": "2.1"
            },
            {
              "version": "2.2",
              "status": "unaffected"
            }
          ]
        }
      ]
    }
  }
}