CVE-2019-15803
CVE.org · Publicado
- Status do registro
- Publicado
- Ano do identificador (não é o ano de publicação)
- 2019
- Publicação na fonte
- Atualização na fonte
- Importado pelo cveboard
- Snapshot da fonte
- cve_2026-10-24_midnight_baseline ·
Texto da CNA em inglês
An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Through an undocumented sequence of keypresses, undocumented functionality is triggered. A diagnostics shell is triggered via CTRL-ALT-t, which prompts for the password returned by fds_sys_passDebugPasswd_ret(). The firmware contains access control checks that determine if remote users are allowed to access this functionality. The function that performs this check (fds_sys_remoteDebugEnable_ret in libfds.so) always return TRUE with no actual checks performed. The diagnostics menu allows for reading/writing arbitrary registers and various other configuration parameters which are believed to be related to the network interface chips.
Fatos de produtos e versões por escopo
Dados de correção desconhecidos; nenhuma versão corrigida é deduzida aqui. Dados ausentes não comprovam ausência de correção.
Exploração desconhecida; este catálogo não avalia exploração.
n/a
- Fornecedor
- n/a
- Produto
- n/a
- Plataformas
- Desconhecido
- Status padrão
Desconhecido
| Versão (version) | Status (status) | Esquema de versões (versionType) | Fim exclusivo (lessThan) | Fim inclusivo (lessThanOrEqual) | Mudanças de status (at → status) |
|---|---|---|---|---|---|
| n/a | affected | Indisponível | Indisponível | Indisponível | Nenhuma listada |