cveboard Feed RSS

CVE-2022-26364

CVE.org · Publicado

Histórico de CVEsJSONInstruções para IA

Status do registro
Publicado
Ano do identificador (não é o ano de publicação)
2022
Publicação na fonte
Atualização na fonte
Importado pelo cveboard
Snapshot da fonte
cve_2026-10-24_midnight_baseline ·

Texto simples

Texto da CNA em inglês

x86 pv: Insufficient care with non-coherent mappings T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Xen maintains a type reference count for pages, in addition to a regular reference count. This scheme is used to maintain invariants required for Xen's safety, e.g. PV guests may not have direct writeable access to pagetables; updates need auditing by Xen. Unfortunately, Xen's safety logic doesn't account for CPU-induced cache non-coherency; cases where the CPU can cause the content of the cache to be different to the content in main memory. In such cases, Xen's safety logic can incorrectly conclude that the contents of a page is safe.

Fatos de produtos e versões por escopo

Dados de correção desconhecidos; nenhuma versão corrigida é deduzida aqui. Dados ausentes não comprovam ausência de correção.

Exploração desconhecida; este catálogo não avalia exploração.

xen

Fornecedor
Xen
Produto
xen
Plataformas
Desconhecido
Status padrão
Desconhecido
xen · Fatos de produtos e versões por escopo
Versão (version)Status (status)Esquema de versões (versionType)Fim exclusivo (lessThan)Fim inclusivo (lessThanOrEqual)Mudanças de status (at → status)
consult Xen advisory XSA-402unknownIndisponívelIndisponívelIndisponívelNenhuma listada