Buffer overflow on HUB descriptor in Azure RTOS USBX
Azure RTOS USBX is a USB host, device, and on-the-go (OTG) embedded stack. In versions prior to 6.1.10, an attacker can cause a buffer overflow by providing the Azure RTOS USBX host stack a HUB descriptor with `bNbPorts` set to a value greater than `UX_MAX_TT` which defaults to 8. For a `bNbPorts` value of 255, the implementation of `ux_host_class_hub_descriptor_get` function will modify the contents of `hub` -> `ux_host_class_hub_device` -> `ux_device_hub_tt` array violating the end boundary by 255 - `UX_MAX_TT` items. The USB host stack needs to validate the number of ports reported by the hub, and if the value is larger than UX_MAX_TT, USB stack needs to reject the request. This fix has been included in USBX release 6.1.10.
Fatos de produtos e versões por escopo
Dados de correção desconhecidos; nenhuma versão corrigida é deduzida aqui. Dados ausentes não comprovam ausência de correção.
Exploração desconhecida; este catálogo não avalia exploração.
usbx
- Fornecedor
- azure-rtos
- Produto
- usbx
- Plataformas
- Desconhecido
- Status padrão
Desconhecido
| Versão (version) | Status (status) | Esquema de versões (versionType) | Fim exclusivo (lessThan) | Fim inclusivo (lessThanOrEqual) | Mudanças de status (at → status) |
|---|---|---|---|---|---|
| < 6.1.10 | affected | Indisponível | Indisponível | Indisponível | Nenhuma listada |