cveboard Feed RSS

CVE-2024-43663

CVE.org · Publicado

Histórico de CVEsJSONInstruções para IA

Status do registro
Publicado
Ano do identificador (não é o ano de publicação)
2024
Publicação na fonte
Atualização na fonte
Importado pelo cveboard
Snapshot da fonte
cve_2026-10-24_midnight_baseline ·

Texto simples

Texto da CNA em inglês

Buffer overflow vulnerabilities in CGI scripts lead to segfault

There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities. Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect  this vulnerability to have a safety impact. The attack can be automated (AU:Y).

Fatos de produtos e versões por escopo

Dados de correção desconhecidos; nenhuma versão corrigida é deduzida aqui. Dados ausentes não comprovam ausência de correção.

Exploração desconhecida; este catálogo não avalia exploração.

Iocharger firmware for AC models

Fornecedor
Iocharger
Produto
Iocharger firmware for AC models
Plataformas
Desconhecido
Status padrão
unaffected
Iocharger firmware for AC models · Fatos de produtos e versões por escopo
Versão (version)Status (status)Esquema de versões (versionType)Fim exclusivo (lessThan)Fim inclusivo (lessThanOrEqual)Mudanças de status (at → status)
0affectedcustom24120701IndisponívelNenhuma listada