CVE-2026-50577
CVE.org · Published
- Record status
- Published
- Identifier year (not publication year)
- 2026
- Source publication
- Source updated
- Imported by cveboard
- Source snapshot
- cve_2026-10-24_midnight_baseline ·
CNA source text (English)
ePA 3.x Integration: AES-GCM Nonce Reuse via Frozen VAU Request Counter
ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration leaves request_counter unchanged in app/vau/VAUProtokoll.py while constructing VAU messages. The frozen client request counter causes the server side to reuse AES-GCM nonce and key combinations across responses. A network attacker who collects repeated ciphertexts can recover the XOR of plaintexts and use predictable inner HTTP headers and JSON fields to recover sensitive data, including patient health records. Repeated nonces can also enable recovery of the GHASH authentication key through the Joux forbidden attack, allowing forged AES-GCM messages and injection of malicious responses. The response-counter check also fails to maintain last_response_counter, weakening replay and ordering validation. This issue is fixed in version 1.3.0.
Scoped product and version facts
Fix information unknown; no fixed version is derived here. Missing information does not prove that no fix exists.
Exploitation unknown; this catalogue does not assess exploitation.
ePA3-Service-OpenSource
- Vendor
- fbeta-GmbH
- Product
- ePA3-Service-OpenSource
- Platforms
- Unknown
- Default status
Unknown
| Version (version) | Status (status) | Version scheme (versionType) | Exclusive end (lessThan) | Inclusive end (lessThanOrEqual) | Status changes (at → status) |
|---|---|---|---|---|---|
| < 1.3.0 | affected | Unavailable | Unavailable | Unavailable | None listed |