cveboard Feed RSS

CVE-2026-50577

CVE.org · Publicado

Histórico de CVEsJSONInstruções para IA

Status do registro
Publicado
Ano do identificador (não é o ano de publicação)
2026
Publicação na fonte
Atualização na fonte
Importado pelo cveboard
Snapshot da fonte
cve_2026-10-24_midnight_baseline ·

Texto simples

Texto da CNA em inglês

ePA 3.x Integration: AES-GCM Nonce Reuse via Frozen VAU Request Counter

ePA 3.x Integration implements the authorization workflow and writes Medical Information Objects to Germany's electronic patient record. Prior to 1.3.0, ePA 3.x Integration leaves request_counter unchanged in app/vau/VAUProtokoll.py while constructing VAU messages. The frozen client request counter causes the server side to reuse AES-GCM nonce and key combinations across responses. A network attacker who collects repeated ciphertexts can recover the XOR of plaintexts and use predictable inner HTTP headers and JSON fields to recover sensitive data, including patient health records. Repeated nonces can also enable recovery of the GHASH authentication key through the Joux forbidden attack, allowing forged AES-GCM messages and injection of malicious responses. The response-counter check also fails to maintain last_response_counter, weakening replay and ordering validation. This issue is fixed in version 1.3.0.

Fatos de produtos e versões por escopo

Dados de correção desconhecidos; nenhuma versão corrigida é deduzida aqui. Dados ausentes não comprovam ausência de correção.

Exploração desconhecida; este catálogo não avalia exploração.

ePA3-Service-OpenSource

Fornecedor
fbeta-GmbH
Produto
ePA3-Service-OpenSource
Plataformas
Desconhecido
Status padrão
Desconhecido
ePA3-Service-OpenSource · Fatos de produtos e versões por escopo
Versão (version)Status (status)Esquema de versões (versionType)Fim exclusivo (lessThan)Fim inclusivo (lessThanOrEqual)Mudanças de status (at → status)
< 1.3.0affectedIndisponívelIndisponívelIndisponívelNenhuma listada